• A Study on the Treatment of Soil Flushing Effluent Using Electrofloatation : Effects of Electrolyte and pH
  • 전기부상을 이용한 토양세정 유출수 처리에 관한 연구 : 전해질 및 pH의 영향
  • 소정현;최상일;조장환;
  • 광운대학교 환경공학과;광운대학교 환경공학과;광운대학교 환경공학과;
Abstract
The optimal operation conditions of electrofloatation for oil-water separation of soil flushing effluent including electrolyte and pH were investigated. The reactor (200 ${\times}$ 10 ${\times}$ 15 cm) for the experiment was constructed by using acrylic plate. Diesel concentration was 1,000 mg/L in the 1 % mixed surfactant solution ($POE_5$: $POE_{14}$ 1: 1). Titanium coated electrode was used as cathode and stainless steel electrode as anode. Reaction time was 62 minutes (reaction time: 60 min., flotation time: 2 min.) and voltage was 6 V. The separation efficiency of electrofloatation was improved to 40% by electrolyte addition. Furthermore, NaCl (1N) added as electrolyte was showed enhanced efficiency compared to NaOH (1N). While, the effect of both NaCl and NaOH was sequentially increased in the range of 0.2∼1.0% (0.02∼0.1 M). The equilibrium time was found as 20 min. in the range of 0.4∼1.0% (0.04∼0.1M) for both of them.

전기분해에 의한 부상현상을 이용하여 유류로 오염된 토양 세정 후 발생되는 유출수 중 유분 등을 분리하기 위한 적정 운전조건을 찾고자 하였다. 전기분해 반응조(200${\times}$10${\times}$15cm)를 이용하여 혼합계면활성제($POE_5$ : $POE_{14} $, 1:1) 1%용액에 디젤을 1,000 mg/L 농도로 용해시켜 실험하였다. 양극에는 티타늄 코팅전극, 음극으로는 스테인레스 스틸전극을 이용하였다. 반응시간은 62분(반응 :60분, 부상시간 :2분)이었으며 전압은 6V였다. 전해질 첨가에 의한 영향을 알아보기 위하여 실험한 결과, 전해질을 첨가하였을 경우 첨가하지 않았을 때보다 40% 정도의 효율이 증가하였다. 적정 전해질, 주입농도 및 반응시간을 알아보기 위하여 1N NaCl과 NaOH의 농도를 변화시켜 가면서 실험하였다. NaCl의 경우 더 좋은 효율을 나타내었다. 전해질의 농도는 0.2-1.0%의 농도범위에서 NaCl와 NaOH 모두 농도에 따라 순차적으로 효율이 증가하였다. 두 전해질 모두 0.4-1.0% 농도 범위에서 평형에 도달하는 시간은 20분으로 나타났다.

Keywords: flushing effluent;oil-water separation;electrolysis;electrofloatation;

Keywords: 토양세정 유출수;유수분리;전기분해;전기부상;

This Article

  • 2003; 8(3): 56-60

    Published on Sep 1, 2003

Correspondence to

  • E-mail: