• Effects of Selected Time on Analysis Results in Step-Drawdown Tests
  • Lee Jin-Yong;Song Sung-Ho;Lee Kang-Kun;
  • GeoGreen21 Co., Ltd.;Rural Research Institute, KARICO;School of Earth and Environmental Sciences, Seoul National University;
  • 단계양수시험 해석시 시간선택이 해석결과에 미치는 영향
  • 이진용;송성호;이강근;
  • 지오그린21;농업기반공사 농어촌연구원;서울대학교 지구환경과학부;
Abstract
Step-drawdown test has been generally conducted to evaluate productivity or efficiency of both aquifer and well. In general step-drawdown test, pumping with a low constant discharge rate is conducted in the first stage until the drawdown within the well stabilizes. And then the groundwater is pumped with a higher rate in the next step until the drawdown stabilizes once more. This process is repeated at least three times (steps), with the equal duration. In this paper we tried to review some critical problems related to the step-drawdown test, which were revealed in the process of field practices and analyses. The problems, referred in this paper are mainly associated with the incorrect conceptual approach for analysis and incomplete data collection in the field test.

단공 수리시험으로서의 단계양수시험은 일반적으로 대수층 및 우물의 생산성 혹은 효율을 평가하기 위해 수행되어 왔다. 단계양수시험은 기본적으로 초기에 저양수량으로 양수를 하며 양수관정의 수위가 안정되면 다음 단계의 고양 수량으로 다시 수위가 안정될 때까지 양수를 지속한다. 이러한 과정은 최소 3단계 이상 반복되며 각 단계별 양수지속시간을 동일하여야 한다. 본 기술자료에서는 그 동안 국내에서 수행된 단계양수시험의 해석과 관련하여 몇 가지 문제점들을 살펴보았다. 그 결과 단계양수시험에 대한 부적절한 해석결과는 주로 잘못된 해석개념 및 불완전한 현장 양수자료와 관계가 큰 것으로 파악되었다.

Keywords: Step-drawdown test;Well loss;Aquifer loss;Productivity;Well efficiency;Pumping duration;

Keywords: 단계양수시험;우물손실;대수층 손실;생산성;우물 효율;양수지속시간;

This Article

  • 2005; 10(2): 59-65

    Published on Apr 1, 2005

Correspondence to

  • E-mail: