• A Study on BTEX Removal Efficiency for Variation of Moistures by Microwave Process
  • Ha, Sang-An;Yeom, Hae-Kyong;Yu, Mi-Yong;
  • Department of Environmental Engineering, Silla univeristy;Department of Environmental Engineering, Silla univeristy;Department of Environmental Engineering, Silla univeristy;
  • 유류오염토의 마이크로파 처리 시 토양의 함수율 변화에 따른 BTEX 제거특성에 관한 연구
  • 하상안;염혜경;유미영;
  • 신라대학교 환경공학과;신라대학교 환경공학과;신라대학교 환경공학과;
Abstract
This study has been focused on an application of microwave pre-treatment of soil contaminated with volatile organic chemicals, and BTEX(benzene, toluene, ethylene, xylene). Microwave experiments were carried out under different power conditions (2 kW, 4 kW) using different moisture contents and BTEX concentration. According to these results of this study, the most BTEX removal efficiency was with 20% moisture contents regardless of electric power. The result show that 2kW was determined to the optimum electric power at $10{\sim}30%$ moisture contents, but the optimum power was 4 kW at 50% of moisture content.

토양복원의 기술로 마이크로파를 이용할 시 휘발성물질((PAH)s 등)) 및 준휘발성((PCB)s 등) 물질 등을 처리하는데 효과적인 것으로 알려져 있다. 본 연구에서는 휘발성 물질인 BTEX를 마이크로파를 이용하여 수분변화 및 전력변화에 따른 제거특성을 연구하였다. 10%, 20%, 30%, 50%의 함수율 변화에 따른 BTEX 제거율은 20%일 때가 제거율이 가장 높음을 제거상수를 통해 도출할 수 있었으며, 전력의 변화에 따른 BTEX 제거율 및 제거율에 도달하는 시간은 비슷한 것으로 나타났다. 각각 다른 함수율이 마이크로파 처리 시 한계함수율에 도달하는 시간을 측정한 결과, 한계함수율에 도달하는 시간은 함수율이 10%, 20%, 30%일 때는 2 kW와 4 kW는 큰 차이가 없음을 알 수 있었고, 함수율이 50%일 경우는 한계함수율에 도달하는 시간이 4kW가 더 빠른 것으로 나타났다. 수분함수율에 따른 최적전력을 도출하면 수분함량이 $10{\sim}30%$ 시 2 kW가 경제적으로 나타났으며, 함수율이 50% 일 경우는 전력이 4 kW일 때 경제적인 것으로 나타났다.

Keywords: Microwave;BTEX;Electric power;

Keywords: 마이크로파;전력;

This Article

  • 2007; 12(2): 65-71

    Published on Apr 30, 2007

Correspondence to

  • E-mail: