• Performance Evaluation of Soil Vapor Extraction Using Prefabricated Vertical Drain System
  • Shin, Eun-Chul;Park, Jeong-Jun;
  • Department of Civil & Environmental System Engineering, Univ. of Incheon;Research Institute for Engineering and Technology, Univ. of Incheon;
  • 연직배수시스템을 이용한 토양증기추출공법의 성능 평가
  • 신은철;박정준;
  • 인천대학교 토목환경시스템공학과;인천대학교 공학기술연구소;
References
  • 1. 신은철, 박정준, 노정민, 2005, 연직배수재를 이용한 오염토양복원 특성 평가, 2005년 한국지반공학회 봄학술발표회, 한국지반공학회, 한국시설안전기술공단, p. 1400-1407
  •  
  • 2. 정하익, 이용수, 우제윤, 1995, 오염지반 및 지하수 정화기술에 관한 연구, KICT/94-GE-1101-2, 한국건설기술연구원
  •  
  • 3. Atkinson, M.S. and Eldred, P.J.L., 1981, Consolidation of soil using vertical drains, Geotechnique, 31(1), 33-43
  •  
  • 4. Bowders, J.J. and Gabr, M.A., 1995, Strip-drains for in silty clean up of contaminated fine-grained soils, Geotechnical News, 13(3), 21-25
  •  
  • 5. Collazos, O.M., Bowders, J.J., and Bouazza, M., 2002, Enhanced soil vapor extraction using PV drains, 4th ICEG Environmental Geotechnics, Sweta & Zeitlinger, Brazil, p. 761-766
  •  
  • 6. Gabr, M.A., Bowders, J.J, Wang, J., and Quaranta, J.D., 1996, In situ soil flushing using prefabricated vertical drains, Canadian Geotechnical Journal, 33(1), 97-105
  •  
  • 7. Gabr, M.A., Williamson, A., Sabodish, M., and Bowders, J.J., 1999, BTEX extraction from clay soil using prefabricated vertical drains, J. Geotech. & Geoenviron. Engrg., 125(3), 615-618
  •  
  • 8. Hansbo, S., 1979, Consolidation of clay by band-shaped prefabricated drains, Ground Engrg., 12(5), 16-25
  •  
  • 9. Johnson, P.C., Stanley, C.C., Kemblowsky, D.L., Byers, D.L., and Colthart, J.D., 1990, A practical approach to the design, operating, and monitoring of in-situ soil venting systems, Ground Water Monitoring Review, 10, 159-178
  •  
  • 10. Long, R. and Covo, A., 1994, Equivalent diameter of vertical drains with an oblong cross section, J. Geotech. Engrg., 120(9), 1625-1630
  •  
  • 11. Theis, C.V., 1935, The relation between the lowering of the piezometric surface and the rate and duration of discharge of a well using groundwater storage, Transactions of the American Geophysical Union 2, 519-524
  •  
  • 12. US EPA, 1995, How to evaluate alternative cleanup technologies for underground storage tank sites: A guide for corrective action plan reviewers, EPA/510/B-95/007, Chapter II, p. 1-29
  •  
  • 13. US EPA, 1997, Remediation case studies: Soil vapor extraction and other in situ technologies, EPA/542/R-97/009
  •  
  • 14. Welker, A.L., Logan, M., and Knight, S.B., 1998, Design issues of a prefabricated drain remediation system, Geotechnical News, 16(1), 31-35
  •  
  • 15. Welker, A.L., Gilbert, R.B., and Bowders, J.J., 2000, Using a reduced equivalent diameter for prefabricated vertical drain to account for smear, Geosynthetics International, 7(1), 47-57
  •  

This Article

  • 2007; 12(5): 9-18

    Published on Oct 31, 2007

Correspondence to

  • E-mail: