The purpose of this study is to evaluate a laboratory test on arsenic reduction efficiency for ARD (Acid Rock Drainage) using limestone and apatite, and to design an apatite drain system. As a result of the laboratory test, results of this study show that pH, arsenic removal ratio, and dissolution amount of limestone & apatite are inversely proportional to flow rates, and apatite removes 100% of arsenic at 0.6 ml/min/kg flow rate. It is supposed that dissolution rate of apatite is ten times higher than that of limestone. The arsenic compounds are assumed to be Johnbaumnite, and/or Ca-arsenic hydrate. According to the results of the laboratory test, apatite drain system is designed as follow; Sixty two tons of apatite will be needed per one year and six months, and the precipitates will be removed from the precipitation pond per 3 months.
본 연구의 목적은 석회석 및 인회석을 이용한 실내실험을 실시하여 ARD 내의 비소저감 효율성을 평가하고 인회석 배수 체계를 설계하는 것이다. 실내실험 결과, pH, 비소저감율 및 석회석/인회석의 용해량은 유속에 반비례 하였으며 인회석은 유속 0.6 ml/min/kg에서 비소를 100% 제거하였다. 인회석의 용해율은 석회석보다 10배 정도 높은 것으로 사료된다. 비소화합물은 비산염인회석 그리고/또는 칼슘비산염수화물의 형태인 것으로 추측된다. 실내실험에 근거하여 인회석 배수체계를 설계하였으며 그 결과는 다음과 같다; 1년 6개월 마다 인회석 62톤을 새로 충진시켜줘야 하며 침전물은 매 3개월 마다 침전조에서 제거해줘야 할 것이다.
Keywords: laboratory test;ARD;limestone;apatite;precipitates;
Keywords: 실내실험;석회석;인회석;침전물;