The Low Temperature Thermal Desorption (LTTD) System equipped with a soil transfer unit, a rotary kiln, RTO, cyclones and a bag filter etc. was developed. The LTTD system was designed to be economically operated using LPG as a fuel and recirculating the discharged gas from the LTTD system through RTO. For the performance test of LTTD system the soil contaminated with light and heavy oils (2,690 mg TPH/kg soil) and with particle sizes below 50 mm was fed into the rotary kiln of LTTD system at 7
$m^3$/hr with retention time of 15 minutes. Operation temperatures of LTTD system for the removal of soil TPH were
$567^{\circ}C$ and
$692^{\circ}C$. The residual TPH after treatment was 46 mg/kg and 32mg/kg respectively at each temperature condition, which shows high TPH removal efficiencies of the developed LTTD as 98.3% and 98.9%.
본 연구에서는 토양 이송 장치, 로터리킬른, RTO, 사이클론 및 백필터 등으로 구성되어 있고 이동이 가능한 저온열탈착 장치를 제작하여 현장유류오염토양의 처리시험을 수행하였다. 제작된 열탈착장치는 LPG를 연료로 사용하고 배출되는 가스를 RTO를 통하여 재순환하는 방식을 적용하여 경제적인 운전이 가능하도록 하였다. 장치의 현장시험을 위하여 경유와
$C_30$ 이상의 heavy oil로 혼합 오염된 현장토양(2,690 mg TPH/kg soil) 을 먼저 선별기를 통해 50 mm 이하의 입경을 가진 토양으로 채 분리한 후, LTTD 장치의 로터리킬른에 체류시간 15분 조건에서 시간당 7
$m^3$의 양으로 투입하였다. 열탈착장치의 온도를 각각 평균
$567^{\circ}C$와
$692^{\circ}C$로 조정한 후 오염토양의 정화 운전을 수행한 결과, 배출되는 정화토양의 TPH 농도는 각각 46 mg/kg과 32 mg/kg로서 각각 평균 98.3과 98.9%의 높은 정화 효율을 얻을 수 있었다.
Keywords: Low Temperature Thermal Desorption (LTTD);TPH;Soil remediation;
Keywords: 저온열탈착;토양정화;