• A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment
  • Jo, Yun-Ju;Lee, Jin-Yong;Lim, Soo-Young;Hong, Gyeong-Pyo;
  • Department of Geology, Kangwon National University;Department of Geology, Kangwon National University;Soil & Ground Water Management Division, Ministry of Environment;Soil & Ground Water Management Division, Ministry of Environment;
  • 지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰
  • 조윤주;이진용;임수영;홍경표;
  • 강원대학교 지질학과;강원대학교 지질학과;환경부 토양지하수과;환경부 토양지하수과;
Abstract
Recently use of renewable energies such as geothermal energy for space heating and cooling is increasing in Korea due to energy crisis and global warming. Ground source heat pump (GSHP) is known as one of the most environment-friendly HVAC (heating, ventilation and air-conditioning) systems in the world. However, some potential effects caused installation and operation of the GSHP systems on soil and groundwater environment are reported. The potential effects are closely related with inappropriate installation, operation and closure of the GSHP systems. In this paper, possible effects of the GSHPs on soil and groundwater environments are reviewed.

최근 에너지 위기와 지구 온난화의 영향으로 국내에서 건물의 냉난방에 지열에너지를 비롯한 재생에너지의 사용이 증가하고 있다. 지열히트펌프시스템은 지금까지 지구상에서 가장 환경친화적인 냉난방 공조설비의 하나로 알려져 있다. 그러나 지열히트펌프시스템의 설치 및 운영이 토양 지하수환경에 미칠 수 있는 몇 가지 영향들에 대한 보고가 있다. 이들 영향으로는 주로 지열히트펌프시스템의 부적절한 설치, 운영 및 폐쇄와 관련된다. 본 논문에서는 지열히트 펌프시스템이 토양 지하수환경에 미칠 수 있는 영향에 관하여 고찰하였다.

Keywords: Ground source heat pump;Renewable energy;Geothermal energy;Soil;Groundwater;

Keywords: 지열히트펌프;재생에너지;지열에너지;토양;지하수;

References
  • 1. 강신형, 2007, 건축설계시 지열설비 적용 방안: 우리의 지구, 땅의 열을 에너지원으로. 신재생에너지 설치의무화 기술세미나, aT센터
  •  
  • 2. 김형수, 김충환, 김병군, 백건하, 최현숙, 2002, 충적층 지하수의 철, 망간 기작 및 효율적 처리 방안 연구-강변여과수 개발 현장을 중심으로. 한국지하수토양환경학회 추계학술대회, 부산대학교, p. 125-128
  •  
  • 3. 대한광업진흥공사, 2007, 지열에너지의 이용 현황 및 향후 전망. 대한광업진흥공사, p. 19
  •  
  • 4. 신.재생에너지센터, 2008, 지열. 에너지관리공단 신.재생에너지 센터 홈페이지, www.knrec.or.kr, Access at August 6, 2008
  •  
  • 5. 신현준, 2004, 지열원 열펌프 시스템-관련 기술 및 적용 사례. 공공기관 대체에너지 이용의무화 제도 및 적용모듈 설명회, p. 1-65
  •  
  • 6. 신현준, 2007, 지열원 열펌프 냉난방 시스템의 기술 및 시장 현황. 2007 Geothermal Energy Symposium, IGSHPA-Korea 지열에너지 기술현황과 전망, 한국지열에너지기술지원센터, 강원대학교, p. 62-85
  •  
  • 7. 우정선, 2003, 지열, 지열원 열펌프. ETIS 분석지, 23, 129-142
  •  
  • 8. 이진용, 구민호, 2007, 도시화가 지하수에 미치는 영향 및 도시지역 지하수 문제 고찰. 지질학회지, 43(4), 517-528
  •  
  • 9. 이진용, 천정용, 이명재, 최미정, 김현중, 전선금, 문형준, 전성천, 2006, 인천기지 Pump 고장원인 조사를 위한 이물질 생성원인분석. 초안보고서, E1, p. 104
  •  
  • 10. 이진용, 이종규, 김정우, 김창균, 2008, 지열시스템이 토양·지하수에 미치는 영향에 관한 연구. 최종보고서, 환경부, p. 240
  •  
  • 11. 정하익, 2006, 지열에너지 개발과 토양 및 지하수 오염. 한국지열에너지학회지, 2(1), 31-43
  •  
  • 12. 조정식, 2006, 지중 열교환기 전열성능 향상을 위한 뒤채움재 조성에 관한 연구. 산업자원부, 최종보고서 2004-N-GE08-P-01
  •  
  • 13. 최상규, 2003, 지열히트펌프는 국내 여건에 최적인 대체에너지. 에너지경제신문 2003년 2월 15일자, 한국기계연구원
  •  
  • 14. 최항석, 이철호, 최효범, 우상백, 2008, 지중 열교환기용 뒤채움재의 물리적 특성 연구. 한국지반공학회논문집, 24(1), 37-49
  •  
  • 15. 한국건설기술연구원, 2005a, 지열원 열펌프 설비 공사 시방서. 한국건설기술연구원, 일산, p. 177
  •  
  • 16. 한국수자원공사, 2008, 지하 열 자원 부존,활용 정보시스템 구축: 강변여과수(충적층 및 하상) 열자원 활용 기술. 에너지.자원기술개발 최종보고서, 한국수자원공사, 한국지질자원연구원, p. 178
  •  
  • 17. 한정상, 한혁상, 한찬, 김형수, 전재수, 2006, 수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침. 자원환경지질, 39(5), 607-613
  •  
  • 18. 헤럴드경제, 2008, 상하이 등 무분별 지하수 개발 고강 도로포장영향 빗물 스며들지 않아. 2008년 8월 7일자
  •  
  • 19. Allan, M.L., Philippacopoulos, A.J., 1999, Ground water protection issues with geothermal heat pumps. Geothermal Resources Council Meeting, Reno, NV, p. 9
  •  
  • 20. Andrews, C.B., 1978, Impact of the use of heat pumps on ground-water temperatures. Ground Water, 16(6), 437-443
  •  
  • 21. Armitage, D.M., Bacon, D.J., Massey-Norton, J.T., Miller, J.D., 1980, Ground-Water Heat Pumps: an Examination of Hydrogeologic, Environmental, Legal, and Economic Factors Affecting Their Use. U.S. Department of Energy, Washington, D.C., DOE/CS/20060-5120 (V.1), p. 246
  •  
  • 22. CDPH (Connecticut Department of Public Health), 2007, Recommendation for Regulation of Geothermal Wells. Report to the General Assembly, State of Connecticut, p. 17
  •  
  • 23. DenBraven, K., 1998, Survey of geothermal heat pump regulations in the United States. Proceedings of the Second Stockton International Geothermal Conference, The Richard Stockton College of New Jersey, p. 1-9
  •  
  • 24. Deng, Z., 2004, Modeling of standing column wells in ground source heat pump systems. ph.D thesis, Oklahoma State University, p. 303
  •  
  • 25. Dickson, M.H., Fanelli, M., 1994, Small geothermal resources: A review. Energy Sources, 16(3), 349-376
  •  
  • 26. EBA, 2007, Professional Guidelines for Geoexchange Systems in British Columbia. Part 2-Design. British Columbia, p. 47
  •  
  • 27. EST (Energy Saving Trust), 2007a, Discover Renewable Energy: Using Warmth from the Ground to Heat Your Home. EST, London, p. 4
  •  
  • 28. EST (Energy Saving Trust), 2007b, Domestic Ground Source Heat Pumps: Design and Installation of Closed-Loop Systems-A Guide for Specifiers, Their Advisors and Potential Users. EST, London, p. 24
  •  
  • 29. Heinonen, E.W., Wildin, M.W., Beall, A.N., Tapscott, R.E., 1998, Anti-freeze fluid environmental and health evaluation-an update. Proceedings of the Second Stockton International Geothermal Conference, p. 1-11
  •  
  • 30. Hicks, R.J., Stewart, D.L., 1988, Environmental assessment of the potential effects of aquifer thermal energy storage on microorganism in groundwater. PNL-6492, Pacific Northwest Laboratory, Richard, Washington
  •  
  • 31. IGSHPA (International Ground Source Heat Pump Association), 2007, Closed-Loop/Geothermal Heat Pump Systems: Design and Installation Standards. IGSHPA, OSU, OK, p. 24
  •  
  • 32. Jo, H.Y., Katsumi, T., Benson, C.H., Edil, T.B., 2001, Hydraulic conductivity and swelling of nonprehydrated GCLs permeated with single-species salt solutions. J. Geotech. Geoenvir. Eng., 127(7), 557-567
  •  
  • 33. Johnson, Jr., R.C., Kurt, C.E., Dunham, Jr., G.F., 2006, Well grouting and casing temperature increases. Ground Water, 18(1), 7-13
  •  
  • 34. Kai, Z., Hongwei, F., Lixu, W., 2005, Bacterial growth in a groundwater source heat pump system. J. Tsinghua University (China), 45(12), 1608-1612
  •  
  • 35. Karlsson, F., Axell, M., Fahlen, P., 2003, Heat Pump Systems in Sweden. Country Report for IEA HPP Annex 28, p. 29
  •  
  • 36. Kavanaugh, S.P., Rafferty, K., 1997, Ground-Source Heat Pumps: Design of Geothermal Systems for Commercial and Institutional Buildings. ASHRAE, Atlanta, p. 167
  •  
  • 37. Kim, K., 2003, Long-term disturbance of groundwater chemistry following well installation. Ground Water, 41, 780-789
  •  
  • 38. Klotzbucher, T., Kappler, A., Straub, K.L., Haderlein, S.B., 2007, Biodegradability and groundwater pollutant potential of organic anti-freeze liquids used in borehole heat exchangers. Geothermics, 36, 348-361
  •  
  • 39. Knape, B.K., 1984, Underground Injection Operations in Texas: a Classification and Assessment of Underground Injection Activities. Texas Department of Water Resources, Austin, Texas
  •  
  • 40. Lawrence, A.R., Morris, B.L., Foster, S.S.D., 1998, Hazards induced by groundwater under rapid urbanization. Geohazards in Engineering Geology, Geological Society of London, Engineering Geology Special Publication, 15, 319-328
  •  
  • 41. Lee, J.Y., 2009, Current status of ground source heat pumps in Korea. Renewable & Sustainable Energy Review (in press)
  •  
  • 42. Lee, J.Y., Hahn, J.S., 2006, Characterization of groundwater temperature obtained from the Korean national groundwater monitoring stations: implications for heat pumps. J. Hydrol., 329, 514-526
  •  
  • 43. Lee, J.Y., Won, J.H., Hahn, J.S., 2006, Evaluation of hydrogeologic conditions for groundwater heat pumps: analysis with data from national groundwater monitoring stations. Geosciences J., 10(1), 91-99
  •  
  • 44. MDNR (Missouri Department of Natural Resources), 2004, Rules of Department of Natural Resources Division 23-Division of Geology and Land Survey, Chapter 5-Heat Pump Construction Code. MNDR, Missouri, p. 6
  •  
  • 45. McCray, K.B., 1998, Guidelines for the construction of vertical boreholes for closed loop heat pump systems. Proceedings of the Second Stockton International Geothermal Conference, Stockton College of New Jersey, p. 1-9
  •  
  • 46. Mehnert, E., 2004, The Environmental Effects of Ground-Source Heat Pumps-A Preliminary Overview. Illinois State Geological Survey, ISGS Open-File Series Report 2004-2, p. 9
  •  
  • 47. NRCan (Natural Resources Canada), 2002b, Commercial Earth Energy Systems: A Buyer's Guide. NRCan, Her Majesty the Queen in Right of Canada, p. 89
  •  
  • 48. PADEP (Pennsylvania Department of Environmental Resources), 1996, Ground Source Heat Pump Manual. Bureau of Water Quality Management, Department of Environmental Protection, DEP #1562
  •  
  • 49. Rafferty, K.D., 2001, Design aspects of commercial open-loop heat pump systems. GHC Bulletin, 22, 16-24
  •  
  • 50. Rutherford, S., 2004, Groundwater use in Canada: heat pump. West Coast Environmental Law, p. 1
  •  
  • 51. Rybach, L., 2003, Geothermal energy: sustainability and the environment. Geothermics, 32, 463-470
  •  
  • 52. Snyder, M., Lee, C.H., 1980, Survey of Rejection Experience from Ground Water Cooling Applications. Midwest Research Institute for Pacific Northwest Laboratory, U.S. DOE, DEAC06-76RLO 1830
  •  
  • 53. Sowers, L.S., Epstein, C., York, K.P., van Guilder, B., Jahangir, S., Steinberg, A., Stafford, L., Pierce, J., Brownhill, J., Solomon, T., 1997, Impact of a large scale geothermal project on its surface and subterranean environment. Proceedings of the 7th International Conference on Thermal Energy Storage MEGASTOCK, 1, 85-90
  •  
  • 54. USACE (U.S. Army Corps of Engineers), 2008, Water-Loop and Ground-Loop Heat Pump Systems. UFGS-23 81 47 (April 2008), p. 67
  •  
  • 55. USEPA (United States Environmental Protection Agency), 1993, Space Conditioning: The Next Frontier-The Potential of Advanced Residential Space Heating Technologies for Reduction Pollution and Saving Customers Money. USEPA, Washington, p. 103
  •  
  • 56. USEPA (United States Environmental Protection Agency), 1997, Manual on Environmental Issues Related to Geothermal Heat Pump Systems. USEPA Atmospheric Pollution Prevention Division, Washington, D.C
  •  
  • 57. USEPA (United States Environmental Protection Agency), 1999, The Class V Underground Injection Control Study. Volumn 19, Heat Pump and Air Conditioning Return Flow Wells. USEPA, EPA/816-R-99-014s, p. 60
  •  
  • 58. Williams, A.L., Sveter, 1987, Air conditioning earth coupled water source heat pumps-closed and open-loop systems. Proceedings of International Symposium on Class V Well Technology, Underground Injection Practices Council, Oklahoma City, OK, p. 455-458
  •  
  • 59. Yasukawa, K., Takasugi, S., 2003, Present status of promotion of underground thermal utilization in Japan. Proceedings of European Geothermal Conference (EGC2003), Szeged, Hungary, p. 1-8
  •  
  • 60. York, K.P., Jahangir, Z.M.G.S., Solomon, T., Stafford, L., 1998, Effects of a large scale geothermal heat pump installation on aquifer microbiology. Proceedings of the 2nd Stockton Geothermal Conference, p. 1-8
  •  

This Article

  • 2009; 14(3): 22-31

    Published on Jun 30, 2009

  • Received on Mar 8, 2009
  • Revised on Apr 23, 2009
  • Accepted on May 12, 2009