Estimations of porosity and bulk density, particle size analysis of soli samples, tracer test and slug test were performed in a petroleum contaminated area of Kangwon for understanding characteristics of the aquifer. Porosities of the samples were estimated 0.158~0.257, and bulk densities were estimated as
$1.73\sim2.10\;g/cm^3$. Majority proportion of the soil samples was 0.5~1.0 mm size. In the soil texture triangle, all samples were distributed at sand area. Uniformity coefficients were estimated as 7.71~10.39, and thus all samples were poorly-sorted. In the tracer test, Darcy velocity was estimated to
$4.8\times10^{-6}$ cm/day, effective porosity was 0.175, and longitudinal dispersivity was 0.1 m. According to the slug test, hydraulic conductivities of the test wells were estimated as
$2.243\times10^{-2}\sim1.634\times10^{-2}$ cm/sec. These hydrogeologic parameters can be used for efficient remediation design of the petroleum contaminated area.
Keywords: Petroleum contaminated area;Tracer test;Particle size analysis;Slug test;Hydraulic conductivity;