The processes and rates of groundwater recharge were studied by long-term monitoring of groundwater level and isotopic compositions of precipitation, surface water and groundwater in the Yeosu area. The isotopic compositions of surface water and groundwater were directly related to the precipitation event. It is also shown that the minimum amount of precipitation for infiltration to groundwater is about 20mm. The isotopic variations of groundwater shows that the Isotopic composition of groundwater changed by each precipitation event between June and Sep. 2000 is gradually changed without input of precipitation again. It indicates that the groundwater recharged from the upper part is mixed with the groundwater in reservoir. The infiltration rate of first precipitation event after a dry season is estimated to be 16.5% using isotopic mixing equations. It is expected that the groundwater recharge rate could be estimated more quantitavely, if the isotopic method is combined with the conservative methods.
장기적인 강수량 및 지하수위 관측과 강수, 지표수 및 지하수에 대하여 동위원소모니터링을 수행함으로써, 여수지역 소규모 수계에서의 지표수와 지하수 상관관계 및 지하수의 함양특성을 고찰하였다. 지표수 및 지하수의 동위원소조성은 강우량과 강우의 동위원소조성에 직접적으로 영향을 받고 있음을 보여준다. 또한 강우량이 약 20mm이하일 경우는 강우가 지하수로 침투되지 못함을 나타낸다. 지하수의 동위원소조성은 2000년 6월과 9월사이 발생한 12번의 각 강우사건에 의해 변화된 후, 다시 지하수 저류체의 조정으로 변화되는 양상을 확인하였다. 이는 모니터링된 강우 초기에는 강우가 상층부로부터 지하수체계로 유입되고 있음을 보여준다. 혼합방정식을 이용하면 갈수기 이후 첫 번째 강우의 지하수에 침투비율은 16.5%로 산출된다. 지하수의 함양특성에 대하여 기존 방법과 결부시켜, 보완된 동위원소방법을 적용한다면, 지하수 함양율을 보다 정량적으로 평가할 수 있을 것으로 판단된다.